![visual basic 6.0 tutorial pdf ebook free download visual basic 6.0 tutorial pdf ebook free download](https://2.bp.blogspot.com/-lxvDQGCagiE/Vo8E9MY4F5I/AAAAAAAAI4A/fjxLLzEuPlI/s1600/Visual-Basic-Urdu-Pdf-Free.jpg)
All the fields under the Photometry Header will be filled out with the information contained in the Photometric file.
![visual basic 6.0 tutorial pdf ebook free download visual basic 6.0 tutorial pdf ebook free download](https://www.onlineprogrammingbooks.com/images/visualstudio2017succinctly.jpg)
Select the file L6488.IES, Catalog Number 2PM3N ND 1/3 ADDE 2R and click the Open button. Navigate to the.\program Files\Visual 2.0\Tutorials directory on your hard drive. You will be choosing a 2x4 parabolic louvered fluorescent troffer to light the office space. A dialog box will appear for the assignment of a photometric file.ħ Visual Tutorial Basic Edition 7 2. Under the Photometry Header, click the PHOTOMETRIC FILE button. Select NEXT to go on to Step 3.Ħ Visual Tutorial Basic Edition 6 Step 3 Luminaire 1. Your screen should appear as shown above. Select a 4x2 Ceiling grid from the four ceiling grid options. This value is defaulted to the ceiling height, which is the height we will be locating our recessed lighting fixtures. Under the Luminaire Plane Header, you may enter the mounting height of the Luminaires above the floor. In our example the work plane is located at 2.5 feet (desk height) above the floor, which is the default value of the text box. This is plane at which illuminance values will be calculated. Under the Work Plane Header, you may enter the height of the work plane above the floor. Select NEXT to go on to Step 2.ĥ Visual Tutorial Basic Edition 5 Step 2 Planes 1. Below the Units Header, note that English units (feet) are selected as the model s input units. The reflectances of the interior surfaces of the room (80% for the ceiling, 50% for the walls and 20% for the floor) will be automatically entered in the reflectances text boxes. Under the Reflectances Header, select Commercial from the Standard Reflectances drop down list. On the left side of the form under the Dimensions Header, enter 64, 42 and 10 as the length, width and height of the office space in their respective text boxes. Select NEXT or press ENTER on the keyboard to move on to Step 1.Ĥ Visual Tutorial Basic Edition 4 Step 1 Geometry 1. The first screen you will see is the welcome screen shown below. Step-by-step instructions are displayed at the top of each screen. The Tool is presented in a wizard format with the familiar BACK, NEXT and FINISH buttons located at the bottom of the form to guide you through the design process. Room Height: 10 Work Plane: Desk Height (2.5 ) Ceiling Reflectance: 80% Wall Reflectances: 50% Floor Reflectance: 20% 4 x 2 Ceiling Grid Recessed Parabolic Louvered Fixtures Desired Illuminance: 50fcģ Visual Tutorial Basic Edition 3 Using the Lumen Method Tool The Lumen Method Tool, shown below, is the primary design tool of the Basic Edition and will automatically display each time the Basic Edition is started. In this tutorial, you will be designing the lighting system for an office space with the dimensions and design parameters shown below. When the program is loaded, the Lumen Method Tool will appear. The Visual Splash Screen will be displayed while the program is loading.
#VISUAL BASIC 6.0 TUTORIAL PDF EBOOK FREE DOWNLOAD WINDOWS#
Starting a New Project The first step is to launch the Visual Basic Edition from the Visual Program Group under the Windows TM Start menu. This tutorial assumes that you have read the first four chapters of the Visual Basic Edition User's Guide. Activities include starting a new project, using the Lumen Method Tool, modifying the design, interpreting the results and printing the design. 1 Visual Tutorial Basic Edition 1 Visual Basic Edition TutorialĢ Visual Tutorial Basic Edition 2 Basic Edition Tutorial Introduction In this tutorial, you will use the Visual Basic Edition to create and modify a simple rectangular lighting model.